Hand Lever Type Flush Valve in Toilet (B-02)

  • Model NO.: B-02
  • Open Manner: Quick-Opening
  • Hot or Cold: Cold
  • Connection Form: Thread
  • Trademark: CAG
  • Specification: G3/4"
  • Material: Brass
  • Usage: Sanitary Ware
  • Valve Plug: Rubber Ring
  • Service Life: >5 Years
  • Transport Package: in Box, Stand Ard Export Packi
  • Origin: Kaiping Guangdong China
Item description: flush valve
Material: brass 59
Function: used the toilet flush
Type: hand pressure
Installation method: connect water tank
Delay time: 4 to 6 seconds
1.we  provide one step service ,design ,production and packaging  advantages 
2.top quality ,competitive price and good service 
3. oem  service offered

KAIPING CHAOSHENG SANITARY WARE CO.,LTD
Add:No.19 ZhongXing Road.Plumbing Fitting District
Shuikou Town.Kaiping City.GuangDong.China
Tel:+86-750-2710026  2715482  2727208
Fax:+86-750-2729713
 
Http://www.china-chaosheng.com

Hand Lever Type Flush Valve in Toilet (B-02)

 

Jining Union Machinery And Parts Co., Ltd. Is famous for Solenoid Valve For Rexroth. We can supply many brand solenoid valve for Rexroth

hydraulic seloind valve for rexrothrexroth hydraulic valve

The details are as follow,.

1. Security:
1.1 Corrosive media: the choice of plastic valve solenoid valve and stainless steel; for the corrosive medium must use isolation diaphragm. Example CD-F.Z3CF. Neutral medium, copper alloy should also be used as the valve material of the solenoid valve, otherwise, the valve shell often rust off, especially when the action is not frequent. Ammonia valves can not use copper.
1.2 Explosive environment: you must choose the appropriate level of explosion-proof products, open-air installation or dust should be more occasions use waterproof, dustproof varieties.
3, the nominal pressure solenoid valve should exceed the maximum working pressure in the tube.
Second, the applicability:
2. Media characteristics
2.1 The gas, liquid or mixed state were selected different types of solenoid valve, such as ZQDF for air, ZQDF-Y for liquid, ZQDF-2 (or -3) for steam, otherwise easy to cause malfunction. ZDF series of multi-function solenoid valve is available in the gas. Liquid. The best time to state the media state, the installation users do not have to adjust.
2.2 Different medium temperature product specifications, or the coil will burn, seal aging, seriously affect the life of life.
2.3 Medium viscosity, usually below 50cSt. If more than this value, diameter greater than 15mm with ZDF series of multi-function solenoid valve for special order. Path less than 15mm set high viscosity solenoid valve.
2.4 Media cleanliness should be equipped with a recoil filter valve in front of the solenoid valve, the pressure is low fashion can choose direct acting diaphragm solenoid valve for example CD-P.
2.5 If the medium is directional and does not allow backflow ZDF-N and ZQDF-N need to be used in both directions, please make a special request.
2.6 medium temperature should be selected within the allowable range of the solenoid valve.
3. Pipeline parameters
3.1 According to the requirements of medium flow and pipe connection options valve port and model. For example, the small diameter selection CA5 and Z3F for one pipe to two pipes, ZDF-Z1 / 2 for medium or large diameters. Another example is the control of the convergence of two pipelines, please choose ZDF-Z2 / 1.
3.2 According to the flow and the valve Kv value selected nominal diameter, but also optional with the pipe diameter. Please note that some manufacturers are not marked with Kv value, often the size of the valve hole is smaller than the interface diameter, must not be greedy price low and misleading.
3.3 working pressure
Minimum working pressure differential above 0.04Mpa is optional indirect pilot; Minimum working pressure close to or less than zero must be used direct or step direct.
4. Environmental conditions
4.1 The maximum and minimum temperature of the environment should be selected within the allowable range, if any special orders for overcommitment proposed.
4.2 Ambient high relative humidity and rain drops and other occasions, the election should be waterproof solenoid valve
4.3 The environment often vibration, bump and impact occasions should choose a special variety, such as marine electromagnetic valve.
4.4 In a corrosive or explosive environment should give priority to use according to the safety requirements of corrosion resistance
4.5 If the environmental space is limited, please use multi-function solenoid valve, because it eliminates the need for bypass and three manual valves and easy on-line maintenance.
5. Power conditions
5.1 According to the type of power supply, were selected AC and DC solenoid valve. In general AC power access convenience.
5.2 Voltage specifications exhausted preferred AC220V.DC24V.
5.3 Power supply voltage fluctuations are usually used in the exchange of +% 10% .- 15%, DC allows ±% 10 or so, if ultra poor, to take measures to stabilize the voltage or make special order requirements.
5.4 should be selected according to the power capacity of the rated current and power consumption. Should pay attention to AC starting VA value is higher, in the lack of capacity should be preferred indirect induction solenoid valve.
6. Control accuracy
6.1 Ordinary solenoid valve only open and close two positions, when the control accuracy is high and the parameters are stable, please use multi-position solenoid valve; Z3CF three-position normally open solenoid valve with micro-flow, full-flow and shut. ZDF-Z1 / 1 combination of multi-function solenoid valve with full open, big open, small open, full open four flow.
6.2 Operating time: refers to the electrical signal is turned on or off to the completion of the main valve action time, only the company's patented multi-function solenoid valve can be opened and closed separately adjusted, not only to meet the control accuracy requirements, but also to prevent water hammer damage.
6.3 leakage


The sample given the amount of leakage for the common economic level, if too high, please make a special order.
The reliability:
1, working life, this is not included in the factory test project, a type test project. In order to ensure the quality of regular manufacturers should be selected brand-name products.
2, work standard: long-term work system, repeated short-term work system and short-term work system three. The Company's conventional products are long-term working system, that is, the coil allows long-term power work. For a long time to open the valve only a short time off, it should be used normally open solenoid valve. Used in the short-term work volume and volume again
Large, special orders can be made to reduce power consumption.
3, the working frequency: high frequency of operation, the structure should be preferred direct-acting solenoid valve, the power to listen to the preferred exchange.
4, action reliability
Strictly speaking, this test has not been formally included in the professional standards of our solenoid valves, to ensure that the quality should be selected regular manufacturers of brand-name products. In some occasions, the number of actions is not much, but the reliability requirements are very high, such as fire protection, emergency protection, must not be taken lightly. Particularly important, you should also take two double insurance.
Fourth, economy:
It is one of the criteria used, but must be based on a safe, applicable and reliable economy.
Economy is not only the selling price of the product, but also the priority given to its function and quality as well as the cost of installing maintenance and other accessories.
More importantly, the cost of a solenoid valve in the entire automatic control system in the entire automatic control system and the production line is minimal, if you seek a cheap and missed the early damage caused by the group is huge.

Direct-acting solenoid valve:
Principle: When power is on, the electromagnetic coil generates electromagnetic force to lift the closing piece from the valve seat and the valve opens. When the electric power is off, the electromagnetic force disappears. The spring presses the closing piece on the valve seat and the valve closes.
Features: In vacuum, negative pressure, zero pressure can work normally, but the path generally does not exceed 25mm.
Main products involved in the Hydraulic Pump valve (solenoid valve, piston pump fist products), industrial products, drive modules, servo motors, programmable logic controller PLC, CNC transmission, sensors, power supplies, pneumatic components, industrial instrumentation. Specific main business brands and products are as follows:
Bosch Rexroth rexroth large quantities of industrial hydraulic pneumatic components (solenoid valve, throttle, check valve, proportional valve, servo valve, safety relief valve, flow control valve, pressure reducing valve, regulating valve, pressure relay, proportional amplification Plate, amplifier, axial piston pump, vane pump, gear pump, servo drive, servo motor, pneumatic components, pneumatic valve, cylinder, etc.), 

Some series Model:
Solenoid valve: 4WE6, 4WE10, 4WE16; electro-hydraulic valve: 4WEH10H, 4WEH16, 4WEH25.
Check Valves: S10A, S20A, Z1S, Z2S, SL10, SL20, SV10, SV20, RVP, Cartridge Valves: LC, LFA
Relief valve: DB, DBW, DBET, DBD, ZDB, Z2DB, pressure reducing valve: DR6DP, DR10DP, ZDR6, ZDR10, DR-4X, DR-5X
Throttle valve: Z2FS6, Z2FS10, Z2FS16, Z2FS22; Speed control valve: 2FRM5, 2FRM10, 2FRM16,
Balance Valve: FD12FA, FD12PA, FD12KA, FD16FA, Relay: HED80, HED40, Electronic Unit: VT, 0811
Proportional Directional Valves: 4WRA, 4WRAE, 4WRE, 4WREE, 4WREEM, 4WRH, 4WRZ, 4WRZE, 4WRKE, 4WRBKE, 4WS2EM
High Frequency Directional Valves: 4WRPH, 4WRPEH, 5WRP, 5WRPE, 4WRREH, 4WRP, 4WRPE, 4WRP (E) H, 4WRSE, 4WRSEH, 4WRPNH, 4WRL, 4WRLE, 4WRVE, 4WRGE, 4WRL, 4WRLE, 4WRDE, 3WRCBH, Servo System : HAS, HNL, HCS, HNL
Piston pump: A4VSO, A10VSO, A2FO, Dosing motor: A2FM, A4FM, A10FM / E, Gear pump: 0510, AZPF, Vane pump: PV7
Atos ATOS and Dupuoma DUPLOMATIC Italy, the United States Parker Parker and EATON VICKERS Eaton Vickers hydraulic, Japan YUKEN Yuken pump valve advantage spot series (solenoid valve, pressure switch, piston pump, gear pump, the ratio Valve, globe valve, switch valve, etc.)


Solenoid Valve For Rexroth

Solenoid Valve For Rexroth,Rexroth Solenoid Valve,Solenoid Directional Valve,Rexroth Solenoid Directional Valve

JINING UNION MACHINERY AND PARTS CO., LTD. , https://www.vmpmachineryparts.com